STS GSM data logger communication module
08 August, 2013 | Automated Control Pty LtdThe STS GSM communication module for the STS range of data loggers is a reliable and durable communication module that can be used to assist in the continuous monitoring of ground and surface waters.
Moore Industries SSX and SST safety isolators and splitters
08 August, 2013 | Moore IndustriesThe SSX (2-wire loop-powered) and SST (4-wire) safety isolators and splitters provide reliable isolation and signal conversion for HART data in functionally safe process control settings.
Treotham Treoflex-EMC-UV-3 plus EMC-shielded cables for motors
07 August, 2013 | Treotham Automation Pty LtdTreoflex-EMC-UV-3 plus cables are made with a special construction and are used to supply power to motors from frequency converters while maintaining full electromagnetic compatibility (EMC).
FARO CAM2 SmartInspect inspection and measurement software
07 August, 2013 | FAROFARO CAM2 SmartInspect software is highly suited to take measurements without CAD data.
ifm efector PMDLine O5D and OID photoelectric sensors
07 August, 2013 | ifm efector pty ltdThe PMDLine sensors with photonic mixer device (PMD) technology combine the advantages of long-range, reliable background suppression, visible red light and high excess gain in one unit.
Rockwell Automation FactoryTalk View Site Edition (SE) and Machine Edition (ME) 7.0
06 August, 2013 | Rockwell Automation AustraliaFactoryTalk View Site Edition (SE) and Machine Edition (ME) 7.0 applications, released in early 2013, offer more efficient alarm management, simplified installation, improved user experience and integrated data sharing.
Weidmuller KLBU RC shield clamp
06 August, 2013 | Weidmuller Pty LtdSuitable for use in long or extensive systems, the KLBU RC shield clamp is particularly useful in power plants, sewage plants, wastewater and other industrial facilities.
igus guidefast guiding trough
05 August, 2013 | Treotham Automation Pty LtdThe ‘guidefast’ guiding trough from igus has been developed especially for a lateral mounting to standard carriers of industry and hall cranes, and the modular design and a reduced number of components significantly reduce the installation time.
ABB low inrush current motors
05 August, 2013 | ABB Australia Pty LtdABB has identified the most common requirements for low inrush current (LIC) motors and created a set of pre-calculated motors based on enhanced designs.
Elektro electric actuator drive range
02 August, 2013 | Metal Work Pneumatic Australia Pty LtdThe Elektro range of electric drives has the same overall dimensions as ISO 15552 pneumatic cylinders, allowing replacement of a pneumatic air cylinder without the need for any mechanical alterations.
WIKA PSM01 and PSM02 pressure switches
02 August, 2013 | WIKA AustraliaThe compact model PSM01 and PSM02 instruments achieve a reproducibility of ±2% full scale and are suitable for a broad spectrum of applications.
Atlanta HighForce ZTRS precision planetary rack and pinion drive systems
02 August, 2013 | Motion Technologies Pty LtdThe Atlanta HighForce ZTRS precision planetary rack and pinion drive systems are offered in three different planetary drive styles; with helical or straight (spur) rack and pinion, to meet any application requirements.
Hart 1523 NATA Precision Handheld Thermometer
02 August, 2013 | TechRentalsAvailable to rent, the Hart 1523 NATA Precision Handheld Thermometer accurately measures, graphs and records PRTs, thermocouples and thermistors using a wide measurement range.
Dehn + Sohne BLITZDUCTOR XTU universal voltage lightning and surge arresters
01 August, 2013 | DEHN + SOHNE GmbH + Co KGBLITZDUCTOR XTU arresters are combined lightning and surge arresters that can be used for all voltages from 0 to 180 VDC.
Mettler Toledo GPro 500 TDL in-situ oxygen sensor
01 August, 2013 | Mettler-Toledo LtdThe GPro 500 sensor is a tunable diode laser (TDL) gas analyser, meaning no sample extraction or conditioning is necessary, and it is immune to interference from moisture, dust or background gases.