A life cycle approach to energy management in the process industries
Sunday, 31 July, 2011
In most process industries, the management of energy consumption has become a high priority in recent years. But standalone and ad hoc efforts to manage energy will not achieve the results that can be achieved when a comprehensive life cycle approach is used.
Most companies in the process industries are working hard to reduce their energy consumption and the resulting emissions. But the benefits achieved through stand-alone, one-off projects can be lost over time. In order to be effective in the long run, a comprehensive program is necessary that addresses energy in all aspects of the business, and for each role within the organisation. A holistic, consistent approach will help manufacturing sites to minimise energy consumption and maximise production efficiency.
Four activities for life cycle energy management
Recently there has been renewed interest in reducing energy consumption by industries in all areas of the world. These include concerns about CO2 emissions, cost reduction in the current financial slowdown and energy security, among others. One of the best ways to address all of these issues simultaneously is to improve the energy efficiency of existing operations.
The process industries are not exempt from these pressures. Many such sites have energy and emissions management programs in place or are preparing to implement them. Programs that are ad hoc or limited in scope may produce positive results temporarily; but in order to achieve lasting, sustained improvements, a comprehensive program with well-established goals is required.
An effective energy management program for manufacturers - that is, one that enables an organisation to reduce energy consumption through systematic actions - is multifaceted in that it must involve many people and functions across the organisation.
A comprehensive program that will have lasting positive effects on energy consumption for a complex site will do the following:
As illustrated in Figure 1, these areas work together as pieces of an overall, comprehensive approach to energy management. |
|
Note that these activities involve different people within the organisation, and they occur in different time frames. The design activities are generally done only during the initial engineering phase for a site or during capital projects after the units have been put into service. The maintenance activities are done periodically, often during plant shutdown periods but sometimes online during production for some equipment. The control and operations activities are ongoing and continuous; achieving efficiency through these is addressed daily at the best-managed sites.
Table 1 lists some examples of the types of activities engaged in for the four areas of design, maintenance, automation and operations.
|
Energy management in the design phase
The ultimate energy efficiency of a process unit is, to a large extent, determined during the design phase. Choices made in this stage will have lasting effects through the life of the unit, and they typically constrain the maximum efficiency achievable once the units are in operation. These choices include selection of major equipment, inclusion of unit operations intended to recover low-grade waste heat and even overall technology choices from licensors.
Evaluation of various options will consume time and budget in the design process; so among the most important steps during the design phase is to set aside resources to ensure that energy efficiency is considered early in the process. When energy is simply an add-on activity late in the design phase, and after most major decisions have been made, the only result is often a list of those changes that could have been beneficial but that cannot be investigated without significant delays in the overall project schedule. These changes are almost never implemented, with the resulting lost opportunity affecting the performance through the entire life of the process unit.
Energy management through maintenance
Assuring energy efficiency through maintenance is generally a question of keeping equipment at peak condition, especially rotating equipment and heat transfer operations. While turnarounds and shutdowns are periods of intense maintenance activity, there is often the chance to schedule important cleaning activities even while the plants are in production. Then the question becomes “When is the right time to perform the cleaning operation?”
One method that has been very effective for many installations is real-time monitoring of the performance of critical heat exchangers in fouling services in order to identify when cleaning is cost effective. Changing stream properties and flow rates can make it difficult to know the underlying performance of exchangers, however, and online correction back to a fixed base case is required. One such trend from an operating process is shown in Figure 2.
|
Tracking only the overall heat transfer coefficient U can mask changes. Consider the operating periods marked in the figure. Relatively sharp changes in the observed U value did not indicate rapid fouling, a conclusion that can be noted by comparing the changes during the same period of the U_expected value, which compensates for the process changes, and the calculated fouling factor, which displays the ultimate performance of the exchanger on the right-hand y-axis.
Tracking the underlying condition in detail allowed for the cleaning operations to be scheduled at the right times, as evidenced by the sharp drops in fouling factor at the beginning and again at the end of the time period shown.
Energy management through automation
One of the simplest ways to address energy efficiency through automation is to routinely review the performance of regulatory control loops that affect energy consumption. Often these loops are not flagged by operations for attention from process control staff as long as the loop performance does not affect the production rate or final quality. By identifying and intentionally focusing on these loops periodically, it is often possible to improve energy efficiency without affecting the overall process. Examples are steam/oil ratio controls in oil-fired furnaces, steam pressure controls for sub-headers or individual heat exchangers, plant air header pressure controls, etc. Routinely checking for poor controller tuning, valve stiction and transmitter problems can yield benefits for many plants.
Another activity that can achieve lasting benefits is to review the control structure for ways to reduce energy consumption while meeting all processing objectives. One example that has been implemented in many sites is to set distillation column reflux flow rates to be a ratio of the feed flow rate instead of leaving the flow at a constant value. Some columns can have a similar control strategy for the reboiler duty, varying the heat input with the column throughput. Given the objective and resources, operations and process control staff can work together to identify such opportunities in most sites.
Energy management in operations
Just as process operators are tasked with running their units safely, and meeting production targets for throughput and quality, they can also address and impact energy efficiency. While a necessary first step is to measure and report energy consumption in detail and in real time, it is not sufficient in many cases. When throughput rates, feed properties or product qualities are highly variable, it is critical to also know how much energy should be consumed. This means that operations must be given energy consumption targets that account for current process conditions so that they can spot opportunities to improve.
The importance of this point is illustrated in Figures 3 and 4. The steam consumption and charge rate for an operating refinery’s FCC unit are tracked in Figure 3, where two events of interest are highlighted. In the first, the steam consumption increased for a short time with no change in unit throughput. In the second event, the steam consumption increased with feed rate, as would be expected. When the intelligent targeting information for the unit is added in Figure 4, the picture becomes clearer. The steam consumption targets are shown in blue; for this unit the targets depend on throughput, feed quality and reaction conversion levels. The excursion in steam consumption during the first event is actually worse than indicated at first since the target energy actually decreased during the event (due to process changes other than the throughput). In the second event, although the steam consumption is expected to increase with feed rate, the increase was not executed carefully, such that the steam consumption increased more than it should have. The situation was corrected shortly after the feed rate change, such that the actual consumption was again brought in line with the target rate. Real-time monitoring and reporting of energy consumption will allow operating staff to make moves that result in energy conservation only if the following conditions are met: |
|
|
|
- The energy consumption must be tracked in detail - each energy/utility type, down to at least the process unit level
- The information must be tracked and reported in real time so that responses can be made as soon as a change in performance occurs
- The energy must be put into context by comparing actual consumption to a target consumption that accounts for process conditions such as throughput, feed and product quality, conversion levels, etc.
Each person and function can impact energy efficiency
For the process industries, just as each person and job function has a part to play in ensuring production targets are achieved safely, everyone has a similar opportunity to impact energy efficiency - and most people are anxious to play their part. When each person understands their role and is given the objectives and instructions on how to achieve them, along with the required time and resources, significant and lasting improvements can be expected. A comprehensive energy management program will address efficiency in all stages of the plant’s life cycle, and for each role.
By Rob Brendel, Asia-Pacific Manager - Consulting Services, Honeywell Process Solutions
Anticipating maintenance problems with predictive analytics
By utilising predictive analytics, process manufacturers can predict failures, enhance...
Air-gapped networks give a false sense of security
So-called 'air-gapped' OT networks can still fall victim to cyber attacks, so what is the...
Maximising automation flexibility: the ISV-driven approach
Vendor lock-in has long been a significant barrier to innovation in the industrial sector, making...