Instrumentation

HYDAC LAB 1400 oil condition sensor

08 October, 2014 | Supplied by: HYDAC International

The LAB 1400 sensors are HYDAC's latest compact, multi-function sensors for determining the condition of fluids online.


ESI GS4200 pressure transmitter

30 September, 2014 | Supplied by: ADM Instrument Engineering Group

The ESI GS4200 pressure transmitter incorporate ESI's silicon-on-sapphire sensor technology to give high stability over a wide temperature range.


ifm efector type TW non-contact temperature sensors

26 September, 2014 | Supplied by: ifm efector pty ltd

The TW type non-contact temperature sensors are designed for temperature measurement of hot objects up to 2500°C.


ifm efector VSE series vibration monitoring system

19 September, 2014 | Supplied by: ifm efector pty ltd

The VSE series vibration monitoring systems make it possible to connect accelerometers with IEPE interface as well as a range of MEMS-based VSA vibration sensors over four dynamic channels.


Emerson Micro Motion ELITE CMF350 Coriolis flowmeter

12 September, 2014 | Supplied by: Emerson

The ELITE CMF350 flowmeter features an optimum level of scalability and standardisation for the best fit in applications where flow rate accuracy with low pressure drop and high turndown is critical.


ESI PR3850 pressure transmitter

10 September, 2014 | Supplied by: ADM Instrument Engineering Group

The PR3850 pressure transmitter is suitable for use with high-viscosity materials, typical applications including food processing, pharmaceutical, petrochemical, and wastewater and slurry handling.


Flowmeter calibration management

05 September, 2014 by Ben Keizers and Kyle Shipps*, Endress+Hauser USA | Supplied by: Endress+Hauser Australia Pty Ltd

Failure to calibrate flowmeters can negatively impact performance, while calibrating too frequently can result in excessive costs without providing any benefits. So, the question is, how do you determine if calibration is needed and what the frequency should be?


Dataforth MAQ20 DAQ with IPEmotion software

03 September, 2014 | Supplied by: Scientific Devices Australia

Dataforth Corporation’s MAQ20 data acquisition and control system is now available with IPEmotion software which provides synchronised data acquisition and is easily adaptable to specific customer requirements.


WIKA UPT-20 HART pressure transmitter

01 September, 2014 | Supplied by: WIKA Australia

The WIKA UPT-20 is a HART pressure transmitter featuring HART 7 firmware and a large LCD 4½-digit 14 mm display.


Keller M5 series pressure sensors

29 August, 2014 | Supplied by: KELLER AG für Druckmesstechnik

The design of the M5 series pressure sensor enables dynamic measurements with a bandwidth of 0-50 kHz.


Keller LD series miniature combination pressure and temperature transmitter

26 August, 2014 | Supplied by: KELLER AG für Druckmesstechnik

Claimed to be the smallest fully functional digital combination transmitter for pressure and temperature available, the LD series measures only 11 mm in diameter.


Sierra Instruments QuadraTherm 640i and 780i air flow meters

25 August, 2014 | Supplied by: Procon Instrument Technology

The QuadraTherm 640i and 780i air flow meters have received global approvals for safe operation in potentially hazardous environments from cFMus, ATEX and IECEx.


Flowrox Deposition Watch pipe deposition instrument

22 August, 2014 | Supplied by: Flowrox Pty Ltd

Deposition Watch is an instrument designed to enhance the monitoring of pipelines and related flow-process equipment affected by paraffin wax and asphaltene deposits.


Vendors respond to demand for online analysers with lower cost of ownership

19 August, 2014

Frost & Sullivan has released analysis on the global process analytical instrumentation market, which found that high operating and maintenance costs have prompted customers to demand solutions with lower cost of ownership.


Level instruments aid a spectacular recovery

12 August, 2014 | Supplied by: Endress+Hauser Australia Pty Ltd

The final cruise of the Costa Concordia unexpectedly ended in disaster. But the recovery of the wreck went according to plan, thanks to modern measurement technology.


  • All content Copyright © 2025 Westwick-Farrow Pty Ltd