Crude oil pipeline operator solves flow measurement problem
A regional light crude pipeline operator in the mountain states of the US was looking for an economical, accurate method to measure crude inventory flow within its pumping stations. The pipeline operator specialises in transporting partially processed crude to other lines or main terminals.
Accurate flow measurement is essential to the cost-effective operation of pipelines. While highly precise, and often expensive, flow meters are required to perform custody-transfer measurements for payment purposes, there are also intermediate process measurement points within pumping stations, for example, that can be served with less expensive technology.
When oil is moved over distances via pipelines, pumping stations maintain product throughout as it travels. The flow rate and volume must be monitored to optimise pump operation and throughput to the end destination at a terminal, refinery or point of custody transfer as well as serve as early warning for leak detection.
The regional pipeline company’s process engineers were searching for a low-cost, but accurate flow measurement solution for internal inventory monitoring at its pump stations. There were no custody-transfer requirements and so a flow meter with an accuracy of ±0.5% was deemed suitable.
The light crude in the pipeline had already passed through heaters/treaters or main separators, which left it devoid of gases, water or other constituents that would disturb the specific gravity (SG) of the oil. In this region, the oil has an API gravity rating of 40 or above.
The light crude in the pipeline featured a viscosity of 2–8 centipoise (cP). With various pipeline sizes from 6 to 8″, the liquid velocity varied between 0.3 and 4.9 m/s. Flow meters are mounted at both the pump suction and discharge lines.
The engineering team reviewed several flow meter technologies, including Coriolis, differential pressure, positive displacement and turbine. While all the technologies do measure flow, the team needed to find the specific one that would be the best fit in the crowded pumping station environment. They also needed to look at installation requirements, maintenance and instrument life with a total lifecycle cost perspective to find the most cost-effective solution.
When the pipeline engineering team contacted McCrometer, the company’s applications group suggested the V-Cone flow meter. Featuring a self-conditioning flow technology, the V-Cone flow meter offers a low-installed cost, low-maintenance and highly reliable measurement solution for light crude pipeline pumping station applications. Its no-moving-parts, high-reliability design offers safe, highly stable measurement.
The V-Cone meter offered significant cost savings in light crude pipeline pumping station applications with complex or crowded equipment layouts. It utilises a centrally located intrusion that redirects the flow to the outside of the pipe and conditions the flow by reshaping the velocity profile — all but eliminating the need for straight pipe runs. It requires straight pipe runs of only 0–3 pipe diameters upstream and 0–1 pipe diameters downstream. This smaller footprint, requiring up to 70% less straight pipe without being affected by flow disturbing equipment up or down stream, is more compact than any other differential pressure meters.
The V-Cone flow meter is a differential pressure meter. The principle of operation is based on Bernoulli’s theory of conservation of energy — as the cross-sectional area changes, so must velocity. By placing the cone in the pipe, the cross-sectional area is reduced, forcing velocity of the fluid to increase. As velocity increases, pressure drops, and it is that pressure drop that can be measured and used to determine the fluid flow rate. As the fluid moves past the cone, very short vortices are formed that result in a low-amplitude, high-frequency signal with high stability. The V-Cone maintains ±0.5% accuracy and ±0.1% repeatability over a 10 to 1 turndown and the cone conditions the fluid such that there is relatively low permanent head loss.
The low permanent head loss achieved by the V-Cone meter results from the shape of the cone itself, which minimises energy losses commonly caused by areas of low flow, cavitation and erratic flows. Each V-Cone flow meter is sized to meet desired application requirements and may be specifically designed to have high or low head loss. Regardless, the overall energy consumed by the meter is minimised because of its inherently efficient design characteristics.
The turbulent vortices produced by the V-Cone condition the liquid flow to be homogeneously distributed and extremely stable. It is this turbulent flow that actually protects the cone as well as the surrounding pipe. The turbulent flow forms a boundary layer against the pipe wall and cone, protecting it from particle impingement, which can cause deterioration or build-up on the surfaces.
Normal surface deterioration in flow meters, piping and other equipment occurs as a result of fluid sheer stress. Shear stress creates a problem where there is a solid boundary layer in direct contact with the walls of the pipe. Shear stress occurs in laminar and unstable turbulent flows. The V-Cone’s very stable turbulent flow all but eliminates this shear stress and consequently results in no surface deterioration.
Additionally, due to the shape of the cone, there is little chance of cavitation on the backside of the cone to erode the surface. Each V-Cone is calibrated during the manufacturing process, and because the design is so robust, there is never a need for regular maintenance or recalibration after installation.
With its self-conditioning, no-moving-parts differential pressure (dP) sensing technology, the V-Cone flow meter is now installed in a wide variety of oil production, refining and pipeline applications around the world. Its low-maintenance, no-moving-parts design is proven to remain accurate and all but eliminates the need to shut down production for calibrations, inspections or regular primary element replacement needed for an orifice plate. It saves money by increasing production up-time and reducing labour costs.
Phone: 03 9017 8225
ABB ProcessMaster FEW630 electromagnetic flowmeters
The ProcessMaster FEW630 is an easy-to-use electromagnetic flowmeter for municipal and industrial...
Krohne OPTIWAVE 1520 and 1540 radar level transmitters
Krohne has released the OPTIWAVE 1520 and OPTIWAVE 1540 2-wire 80 GHz radar level transmitters...
Optris Xi 1M spot-finder infrared camera
The Xi 1M from Optris has a resolution of 396 x 300 pixels and is housed in a compact, robust...