Fluke Corporation recalls digital clamp meters

Fluke Australia Pty Ltd
Monday, 11 February, 2013

Fluke Corporation is voluntarily recalling certain digital clamp meters that were manufactured between 1 September 2010 and 1 October 2012. A hazard has been identified in which the printed circuit assembly in these units may not be properly fastened to the test lead input jack. This may result in inaccurate voltage readings, including a low or no voltage reading on a circuit energised with a hazardous voltage, presenting a shock, electrocution or thermal burn hazard.

The products affected are the Fluke 373, 374, 375 and 376 digital clamp meters. This voluntary recall involves Fluke digital clamp meters with the model and serial numbers listed below. Any serial number preceded or followed by the letter ‘R’ is NOT affected by this recall notice.

Model Manufacture dates Starting serial number Ending serial number
Fluke 376 Sep. 2010 - Feb. 2011 14270001 15909999
Fluke 375 Sep. 2010 - Mar. 2011 14270001 16079999
Fluke 374 Oct. 2010 - Feb. 2011 14270001 16379999
Fluke 373 Oct. 2010 - Oct. 2012 14270001 21950000

If you own one of these clamp meters, please stop using it and send it back to Celemetrix Pty Ltd (Fluke Australia’s authorised service provider) for repair. If you are not the primary user of the Fluke 37X Series clamp meter, please pass this notice along to the appropriate people within your organisation. Please send only the clamp meter; any test leads/boxes/manuals that are sent with the unit will NOT be returned.

Fluke has set up a web link to check if a unit is affected by the recall at www.fluke.com/fluke/auen/support/Safety/37X-Recall.htm.

Select your model name, enter the serial number and click the ‘Check’ button. If the unit is within the affected serial number range, contact the local service agent using the link provided, or contact:

Celemetrix Australia Pty Ltd
Service Centre
20 Joseph Street
Blackburn North
VIC 3130
AUSTRALIA
1 (800) 256 838
+61-3-9897-0555
http://www.celemetrix.com.au

Related News

HRS to showcase turnkey processing solutions at APPEX 2024

HRS Heat Exchangers will be showcasing a range of turnkey line solutions for the food and...

HARTING opens production plant in Vietnam

HARTING's new 2500 m2 production site in Hai Duong, Vietnam, will manufacture the...

Oxair and Cobalt Blue combine for future of energy storage

Oxair has supplied its onsite oxygen and nitrogen generators to a Broken Hill mining operation...


  • All content Copyright © 2024 Westwick-Farrow Pty Ltd